The accuracy and quality of the Norbar Static Torque Transducers has made them the first choice of many calibration laboratories throughout the world.
-
Up to 5000 N·m (5000 lbf·ft) classified to BS7882:2008, typically better than Class 1 for the primary classification range (+/-0.5% of reading from 20% to 100% of full scale). - Robust, heat treated, alloy steel torsion shaft design.
- Designed to ignore non torsional forces.
- Operates in clockwise and anti-clockwise directions.
- Calibration up to 100,000 N·m with a UKAS accredited Certificate.
- Calibrated in clockwise direction as standard. Anti-clockwise provided on request.
- 'SMART' transducers have a built in memory circuit which contains essential information about the transducer. This information can be read by Norbar's TST, TTT, TTL-HE & T-Box instruments meaning that when the transducer is connected, it is immediately recognised and ready for use.
- 'SMART' transducers can also be used with many other instruments. However, these will operate as normal ratio calibrated (mV/V) transducers - the 'SMART' data will not be read.
For non Norbar instruments or for when a mV/V certificate is required, use part code suffix ‘.IND’.
S.I Calibrated Transducers
| Capacity | Part No. | Sq. Drive | Dimensions (mm) | Bench Stand | ||
| Nm | # | inch | A | B Ø | C | # |
| 1 | 50587.xxx* | ¼ m/f | 79 | 36.5 | 86 | 50211 |
| 2.5 | 50588.xxx | ¼ m/f | 79 | 36.5 | 86 | 50211 |
| 5 | 50589.xxx | ¼ m/f | 79 | 36.5 | 86 | 50211 |
| 10 | 50590.xxx | ¼ m/f | 79 | 36.5 | 86 | 50211 |
| 25 | 50591.xxx | ⅜ m/f | 79 | 36.5 | 89.5 | 50212 |
| 50 | 50592.xxx | ⅜ m/f | 79 | 36.5 | 89.5 | 50212 |
| 100 | 50593.xxx | ½ m/f | 79 | 36.5 | 92.8 | 50213 |
| 250 | 50594.xxx | ½ m/f | 79 | 36.5 | 92.8 | - |
| 250 | 50701.xxx | ¾ m/f | 118 | 54 | 141 | 50220 |
| 500 | 50596.xxx | ¾ m/f | 118 | 54 | 141 | 50220 |
| 1000 | 50772.xxx | 1 m/f | 118 | 54 | 146 | 50221 |
| 1500 | 50766.xxx | 1 m/f | 118 | 54 | 146 | 50221 |
| 2500 | 50703.xxx | 1½ m/f | 117 | 95 | 160 | 50127.BLK9005 |
| 3000 | 50791.xxx | 1½ m/f | 117 | 95 | 160 | 50127.BLK9005 |
| 5000 | 50599.xxx | 1½ m/f | 117 | 95 | 160 | 50127.BLK9005 |
| 7000 | 50669.xxx | 1½ m/f | 117 | 95 | 160 | 50127.BLK9005 |
| 10000 | 50601.xxx* | 2½ m/m | 68.5 | 110 | 200 | - |
| 10000 | 50776.xxx | 2½ m/f | 145.5 | 130 | 209 | - |
| 25000 | 50603.xxx | 2½ m/m | 68.5 | 110 | 200 | - |
| 25000 | 50797.xxx | 2½ m/f | 145.5 | 130 | 209 | - |
| 50000 | 50781.xxx | 2½ m/f | 145.5 | 130 | 209 | - |
| 50000 | 50794.xxx* | 3½ m/m | 73.5 | 165 | 271 | - |
| 80000 | 50783.xxx | 3½ m/f | 205 | 160 | 291.5 | - |
| 100000 | 50796.xxx | 3½ m/m | 98 | 165 | 271 | - |
*Not suitable for TST and TTT.
Select part no. suffix .LOG if the transducer is to be connected to TST or TTT (example: 50588.LOG). For connection to a non Norbar instrument or when a mV/V cer tif icate is required, select .IND